Panel LCD termoelement-termometer 19mm
- 3 siffrors LCD-display
- K-typ termoelement -200C till +1300C
- J-typ termoelement -130C till +900C
- T-typ termoelement -200C till +350C
- Anslutes med skruvterminaler
- Monteras med ram i panel
DTM 995B är en 3 siffrors LCD termometer med 19mm sifferhöjd och LED bakgrundsbelysning.
Instrumentet kan monteras genom att använda ramen.
Det finns också en IP67-klassad ram att tillgå för vattensäkra applikationer ( seBEZ 900-IP )
Länk till komplett datablad, DTM995B
Specification | Min. | Typ. | Max. | Unit | |
---|---|---|---|---|---|
Probe Measurement range | K-type J-type T-type |
-200 (-328) -130 (-202) -200 (-328) |
+1300 (+1999) +900 (+1652) +350 (+662) |
°C (°F) | |
Accuracy (excluding probe) | 1 (2) | °C (°F) | |||
Supply voltage (normal operation) | 7.5 | 30 | VDC | ||
Supply voltage (5V mode) | 4.75 | 5 | 5.25 | VDC | |
Backlight voltage | 4.75 | 5 | 5.25 | VDC | |
Supply current | 6 (at 30V) | 13 (at 5V) | mA | ||
Supply current with backlighting | 20 (at 30V) | 50 (at 5V) | mA | ||
Operating temperature range | 0 (32) | 50 (122) | °C (°F) | ||
Temperature stability | 0.05 (0.1) | °C (°F) |
* A 5V mode is available by moving DIP switch 2 to the ‘on’ position. Inputting a voltage larger than 5V in this mode may cause permanent damage to the meter. **Backlighting can be run off the internal voltage regulator by moving DIP switch 1 to the on position. Using the backlighting in this way will cause some self heating of the meter. This can be calibrated out during initial setup, however the final application will need to continue using the backlighting to maintain the calibration.
Specification | Min. | Typ. | Max. | Unit | |
---|---|---|---|---|---|
Probe Measurement range | K-type J-type T-type |
-200 (-328) -130 (-202) -200 (-328) |
+1300 (+1999) +900 (+1652) +350 (+662) |
°C (°F) | |
Accuracy (excluding probe) | 1 (2) | °C (°F) | |||
Supply voltage (normal operation) | 7.5 | 30 | VDC | ||
Supply voltage (5V mode) | 4.75 | 5 | 5.25 | VDC | |
Backlight voltage | 4.75 | 5 | 5.25 | VDC | |
Supply current | 6 (at 30V) | 13 (at 5V) | mA | ||
Supply current with backlighting | 20 (at 30V) | 50 (at 5V) | mA | ||
Operating temperature range | 0 (32) | 50 (122) | °C (°F) | ||
Temperature stability | 0.05 (0.1) | °C (°F) |
* A 5V mode is available by moving DIP switch 2 to the ‘on’ position. Inputting a voltage larger than 5V in this mode may cause permanent damage to the meter. **Backlighting can be run off the internal voltage regulator by moving DIP switch 1 to the on position. Using the backlighting in this way will cause some self heating of the meter. This can be calibrated out during initial setup, however the final application will need to continue using the backlighting to maintain the calibration.